Timing-Invariant Reconstruction for Deriving High-Quality CT Angiographic Data from Cerebral CT Perfusion Data

Published Online:https://doi.org/10.1148/radiol.11111068

Timing-invariant CT angiography is a simple and robust technique that yields superior image quality in the evaluation of vascular morphology when compared with standard or dynamic CT angiography of the brain.

Purpose

To suggest a simple and robust technique used to reconstruct high-quality computed tomographic (CT) angiographic images from CT perfusion data and to compare it with currently used CT angiography techniques.

Materials and Methods

Institutional review board approval was waived for this retrospective study, which included 25 consecutive patients who had had a stroke. Temporal maximum intensity projection (tMIP) CT angiographic images were created by using prior temporal filtering as a timing-insensitive technique to produce CT angiographic images from CT perfusion data. The temporal filter strength was optimized to gain maximal contrast-to-noise ratios (CNRs) in the circle of Willis. The resulting timing-invariant (TI) CT angiography was compared with standard helical CT angiography, the arterial phase of dynamic CT angiography, and nonfiltered tMIP CT angiography. Vascular contrast, image noise, and CNR were measured. Four experienced observers scored all images for vascular noise, vascular contour, detail of small and medium arteries, venous superimposition, and overall image quality in a blinded side-by-side comparison. Measurements were compared with a paired t test; P ≤ .05 indicated a significant difference.

Results

On average, optimized temporal filtering in TI CT angiography increased CNR by 18% and decreased image noise by 18% at the expense of a decrease in vascular contrast of 3% when compared with nonfiltered tMIP CT angiography. CNR, image noise, vascular noise, vascular contour, detail visibility of small and medium arteries, and overall image quality of TI CT angiograms were superior to those of standard CT angiography, tMIP CT angiography, and the arterial phase of dynamic CT angiography at a vascular contrast that was similar to that of standard CT angiography. Venous superimposition was similar for all techniques. Image quality of the arterial phase of dynamic CT angiography was rated inferior to that of standard CT angiography.

Conclusion

TI CT angiographic images constructed by using temporally filtered tMIP CT angiographic data have excellent image quality that is superior to that achieved with currently used techniques, but they suffer from modest venous superimposition.

© RSNA, 2012

References

  • 1 Konstas AA, Goldmakher GV, Lee TY, Lev MH. Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. I. Theoretic basis. AJNR Am J Neuroradiol 2009;30(4):662–668.
  • 2 Wintermark M, Rowley HA, Lev MH. Acute stroke triage to intravenous thrombolysis and other therapies with advanced CT or MR imaging: pro CT. Radiology 2009;251(3):619–626.
  • 3 Salomon EJ, Barfett J, Willems PW, Geibprasert S, Bacigaluppi S, Krings T. Dynamic CT angiography and CT perfusion employing a 320-detector row CT: protocol and current clinical applications. Klin Neuroradiol 2009;19(3):187–196.
  • 4 Brouwer PA, Bosman T, van Walderveen MA, Krings T, Leroux AA, Willems PW. Dynamic 320-section CT angiography in cranial arteriovenous shunting lesions. AJNR Am J Neuroradiol 2010;31(4):767–770.
  • 5 Yang CY, Chen YF, Lee CW, et al.. Multiphase CT angiography versus single-phase CT angiography: comparison of image quality and radiation dose. AJNR Am J Neuroradiol 2008;29(7):1288–1295.
  • 6 Willems PW, Brouwer PA, Barfett JJ, terBrugge KG, Krings T. Detection and classification of cranial dural arteriovenous fistulas using 4D-CT angiography: initial experience. AJNR Am J Neuroradiol 2011;32(1):49–53.
  • 7 Barfett JJ, Fierstra J, Mikulis DJ, Krings T. Blood velocity calculated from volumetric dynamic computed tomography angiography. Invest Radiol 2010;45(12):778–781.
  • 8 Siebert E, Bohner G, Dewey M. 320-slice CT neuroimaging: initial clinical experience and image quality evaluation. BrJ Radiol 2009;82(979):561–570.
  • 9 Beier J, Büge T, Stroszczynski C, Oellinger H, Fleck E, Felix R. 2D and 3D parameter images for the analysis of contrast medium distribution in dynamic CT and MRI [in German]. Radiologe 1998;38(10):832–840.
  • 10 Klein S, Staring M, Murphy K, Viergever MA, Pluim JP. elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging 2010;29(1):196–205.
  • 11 Prokop M, Shin HO, Schanz A, Schaefer-Prokop CM. Use of maximum intensity projections in CT angiography: a basic review. RadioGraphics 1997;17(2):433–451.
  • 12 Altman DG. Practical statistics for medical research. Boca Raton, Fla: Chapman & Hall/CRC, 1991; 404.
  • 13 Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010;256(1):32–61.
  • 14 Waaijer A, Prokop M, Velthuis BK, Bakker CJG, de Kort GAP, van Leeuwen MS. Circle of Willis at CT angiography: dose reduction and image quality—reducing tube voltage and increasing tube current settings. Radiology 2007;242(3):832–839.

Article History

Received May 29, 2011; revision requested August 1; revision received September 21; accepted September 27; final version accepted October 6.
Published online: Apr 2012
Published in print: Apr 2012