Abstract
Hybrid iterative reconstruction enables substantial dose reduction for pediatric body CT and maintains acceptable image quality when compared with conventional filtered back projection.
Purpose
To assess image quality and radiation dose reduction with hybrid iterative reconstruction of pediatric chest and abdominal computed tomographic (CT) data compared with conventional filtered back projection (FBP).
Materials and Methods
A total of 234 patients (median age, 12 years; age range, 6 weeks to 18 years) underwent chest and abdominal CT in this institutional review board–approved HIPAA-compliant retrospective study. CT was performed with a hybrid adaptive statistical iterative reconstruction (ASIR)-enabled 64–detector row CT scanner. Scanning protocols were adjusted for clinical indication and patient weight to enable acquisition of reduced-dose CT images in all patients, and tube current was further lowered for ASIR protocols. Weight, age, and sex were recorded, and objective noise was measured in the descending thoracic aorta for chest CT and in the liver for abdominal CT. Of the 234 consecutive patients who underwent ASIR-enabled CT (115 chest and 119 abdominal examinations), 70 patients had undergone prior FBP CT. ASIR and FBP CT studies (29 chest and 41 abdominal studies) in these 70 patients were reviewed for image quality, artifacts, and diagnostic confidence by two pediatric radiologists working independently. Data were analyzed with multiple paired t tests.
Results
Compared with FBP, ASIR enabled dose reduction of 46.4% (3.7 vs 6.9 mGy) for chest CT and 38.2% (5.0 vs 8.1 mGy) for abdominal CT (P < .0001). Both radiologists deemed image quality of and diagnostic confidence with ASIR and FBP CT images as acceptable, without any artifacts. Despite the lower radiation dose used, ASIR images (chest, 10.7 ± 2.5 [mean ± standard deviation]; abdomen, 11.8 ± 3.4) had substantially less objective noise than did FBP images (chest, 13.3 ± 3.8; abdomen, 13.8 ± 5.2) (P = .001, P =.006, respectively).
Conclusion
Use of a hybrid iterative reconstruction technique, such as ASIR, enables substantial radiation dose reduction for pediatric CT when compared with FBP and maintains image quality and diagnostic confidence.
© RSNA, 2012
Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12110268/-/DC1
References
- 1 . Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 2001;176(2):289–296.
- 2 . An approach for the estimation of effective radiation dose at CT in pediatric patients. Radiology 1997;203(2):417–422.
- 3 . Helical CT in children: technical considerations and body applications. Radiology 1998;209(1):37–48.
- 4 . 2006 CT market summary report. Des Plaines, Ill: IMV Medical Information Division, 2006.
- 5 . Helical CT of the body: a survey of techniques used for pediatric patients. AJR Am J Roentgenol 2003;180(2):401–406.
- 6 . Strategies for CT radiation dose optimization. Radiology 2004;230(3):619–628.
- 7 . Radiation from “extra” images acquired with abdominal and/or pelvic CT: effect of automatic tube current modulation. Radiology 2004;232(2):409–414.
- 8 . Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 2004;232(2):347–353.
- 9 . Sixteen-detector row CT of abdomen and pelvis: study for optimization of z-axis modulation technique performed in 153 patients. Radiology 2004;233(1):241–249.
- 10 . Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies. Radiology 2005;235(2):523–529.
- 11 . Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology 2010;256(1):261–269.
- 12 . Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 2010;195(1):126–131.
- 13 . Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 2009;193(3):764–771. [Published correction appears in AJR Am J Roentgenol 2009;193(4):1190.]]
- 14 . Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 2010;45(4):202–210.
- 15 . Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 2010;257(2):373–383.
- 16 . Submillisievert coronary computed tomography angiography using adaptive statistical iterative reconstruction: a new reality. Can J Cardiol 2010;26(1):35–36.
- 17 . Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm—initial clinical experience. Radiology 2010;254(1):145–153.
- 18 . Improved pediatric multidetector body CT using a size-based color-coded format. AJR Am J Roentgenol 2002;178(3):721–726.
- 19 . Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies. Radiology 2009;252(1):200–208.
Article History
Received February 6, 2011; revision requested March 28; revision received July 28; accepted September 16; final version accepted December 29.Published online: May 2012
Published in print: May 2012