Human Gray Matter: Feasibility of Single-Slab 3D Double Inversion-Recovery High-Spatial-Resolution MR Imaging

The purpose of this study was to develop and prospectively evaluate the feasibility of a single-slab three-dimensional (3D) double inversion-recovery, or DIR, sequence for magnetic resonance imaging at 1.5 T. The study was approved by the local ethics committee, and informed consent was obtained from six healthy control subjects (one woman, five men; age range, 26–47 years) and two patients with multiple sclerosis (one woman, aged 39; one man, aged 56). Gray matter (GM)–only images were obtained by selectively suppressing cerebrospinal fluid (CSF) and white matter (WM) signals. Whole-brain high-spatial-resolution 3D images (1.2 × 1.2 × 1.3 mm) were acquired within 10 minutes. Cortical and deep GM structures were clearly delineated from WM and CSF, and there were regional differences in GM signal intensity. No flow artifacts from blood or CSF were observed. These GM images with high spatial resolution are suitable to identify cortical pathologic conditions and can potentially be used for segmentation purposes to determine cortical thickness or volume.

© RSNA, 2006

References

  • 1 Miller DH, Barkhof F, Frank JA, Parker GJ, Thompson AJ. Measurement of atrophy in multiple sclerosis: pathological basis, methodological aspects and clinical relevance. Brain 2002; 125: 1676–1695.
  • 2 Scheltens P, Fox N, Barkhof F, De Carli C. Structural magnetic resonance imaging in the practical assessment of dementia: beyond exclusion. Lancet Neurol 2002;1:13–21.
  • 3 Barkovich AJ, Rowley HA, Andermann F. MR in partial epilepsy: value of high-resolution volumetric techniques. AJNR Am J Neuroradiol 1995;16:339–343.
  • 4 Antel SB, Bernasconi A, Bernasconi N, et al. Computational models of MRI characteristics of focal cortical dysplasia improve lesion detection. Neuroimage 2002;17:1755–1760.
  • 5 Lerch JP, Pruessner JC, Zijdenbos A, Hampel H, Teipel SJ, Evans AC. Focal decline of cortical thickness in Alzheimer's disease identified by computational neuroanatomy. Cereb Cortex 2005;15:995–1001.
  • 6 Geurts JJ, Pouwels PJ, Uitdehaag BM, Polman CH, Barkhof F, Castelijns JA. Intracortical lesions in multiple sclerosis: improved detection with 3D double inversion-recovery MR imaging. Radiology 2005;236:254–260.
  • 7 Redpath TW, Smith FW. Use of a double inversion recovery pulse sequence to image selectively grey or white brain matter. Br J Radiol 1994;67:1258–1263.
  • 8 Turetschek K, Wunderbaldinger P, Bankier AA, Zontsich T. Double inversion recovery imaging of the brain: initial experience and comparison with fluid attenuated inversion recovery imaging. Magn Reson Imaging 1998;16:127–135.
  • 9 Bedell BJ, Narayana PA. Implementation and evaluation of a new pulse sequence for rapid acquisition of double inversion recovery images for simultaneous suppression of white matter and CSF. J Magn Reson Imaging 1998;8:544–547.
  • 10 Boulby PA, Symms MR, Barker GJ. Optimized interleaved whole-brain 3D double inversion recovery (DIR) sequence for imaging the neocortex. Magn Reson Med 2004;51:1181–1186.
  • 11 Pouwels PJ, Kuijer JP, Korf ES, Geurts JJ, Barkhof F. 3D double inversion recovery for high resolution gray matter brain imaging [abstr]. In: Proceedings of the 10th Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2002; 1290.
  • 12 Tan IL, Pouwels PJ, van Schijndel RA, Ader HJ, Manoliu RA, Barkhof F. Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experience. Eur Radiol 2002;12:559–567.
  • 13 Mugler JP, Bao SM, Mulkern RV, et al. Optimized single-slab three-dimensional spin-echo MR imaging of the brain. Radiology 2000;216:891–899.
  • 14 Mugler JP, Kiefer B, Brookeman JR. Three-dimensional T2-weighted imaging of the brain using very long spin-echo trains [abstr]. In: Proceedings of the Eighth Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2000; 687.
  • 15 Kallmes DF, Hui FK, Mugler JP. Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience. Radiology 2001;221:251–255.
  • 16 Zhao L, Mugler JP, Wei X, et al. A high-resolution clinical whole-brain scan using single-slab three-dimensional T1W, T2W and FLAIR fast spin-echo sequences [abstr]. In: Proceedings of the 10th Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2002; 1294.
  • 17 Henkelman RM. Measurement of signal intensities in the presence of noise in MR Images. Med Phys 1985;12:232–233.
  • 18 Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 1995;34:910–914.
  • 19 Hirai T, Korogi Y, Yoshizumi K, Shigematsu Y, Sugahara T, Takahashi M. Limbic lobe of the human brain: evaluation with turbo fluid-attenuated inversion-recovery MR imaging. Radiology 2000;215:470–475.
  • 20 Bendersky M, Rugilo C, Kochen S, Schuster G, Sica RE. Magnetic resonance imaging identifies cytoarchitectonic subtypes of the normal human cerebral cortex. J Neurol Sci 2003;211:75–80.
  • 21 Butman JA, Rebmann AJ. Parcellation of cerebral cortex based on FLAIR signal intensity [abstr]. In: Proceedings of the 12th Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2004; 758.
  • 22 Georgiades CS, Itoh R, Golay X, van Zijl PC, Melhem ER. MR imaging of the human brain at 1.5 T: regional variations in transverse relaxation rates in the cerebral cortex. AJNR Am J Neuroradiol 2001;22:1732–1737.
  • 23 Fischl B, Dale AM. Measuring the thickness of the human cerebral cortex from magnetic resonance images. Proc Natl Acad Sci U S A 2000;97:11050–11055.
  • 24 Meyer JR, Roychowdhury S, Russell EJ, Callahan C, Gitelman D, Mesulam MM. Location of the central sulcus via cortical thickness of the precentral and postcentral gyri on MR. AJNR Am J Neuroradiol 1996;17:1699–1706.
  • 25 van Walderveen MA, van Schijndel RA, Pouwels PJ, Polman CH, Barkhof F. Multislice T-1 relaxation time measurements in the brain using IR-EPI: reproducibility, normal values, and histogram analysis in patients with multiple sclerosis. J Magn Reson Imaging 2003;18:656–664.
  • 26 Griffin CM, Chard DT, Parker GJ, Barker GJ, Thompson AJ, Miller DH. The relationship between lesion and normal appearing brain tissue abnormalities in early relapsing remitting multiple sclerosis. J Neurol 2002;249:193–199.
  • 27 Vaithianathar L, Tench CR, Morgan PS, Lin X, Blumhardt LD. White matter T-1 relaxation time histograms and cerebral atrophy in multiple sclerosis. J Neurol Sci 2002;197:45–50.
  • 28 Steinhoff S, Zaitsev M, Zilles K, Shah NJ. Fast T-1 mapping with volume coverage. Magn Reson Med 2001;46:131–140.

Article History

Published in print: 2006