Intracranial Aneurysms: Treatment with Bare Platinum Coils—Aneurysm Packing, Complex Coils, and Angiographic Recurrence

Purpose: To retrospectively assess, with three-dimensional rotational angiography, the relationship between packing, complex coils, and angiographic recurrence of aneurysms treated with coils.

Materials and Methods: Informed consent was waived by the institutional review board that approved the study. Results at follow-up angiography of 255 aneurysms in 223 patients (161 female and 62 male patients; mean age, 48 years) were dichotomized into presence or absence of recurrence. The degree of packing of aneurysms treated with complex coils alone, with complex and helical coils, and with helical coils only was compared for significant differences. With generalized estimating equations analysis, relative risk (RR) for recurrence was calculated for mode of manifestation, duration of follow-up, aneurysm volume, packing, initial angiographic result, percentage of complex coils, aneurysm location, and multiplicity of aneurysms.

Results: Follow-up angiography revealed recurrence in 28.6% of aneurysms at a mean follow-up of 12 months; 5.5% were amenable to re-treatment. Aneurysms treated with complex and those treated with helical coils only had a mean packing of 27% and 26%, respectively. There was no significant difference between packing of aneurysms treated with complex and those treated with helical coils (P = .538). Recurring and stable aneurysms both had a mean packing of 27%. Generalized estimating equations analysis showed significant differences between duration of follow-up and recurrence (P = .001, RR = 3.39), between aneurysm volume and recurrence (P < .001, RR = 6.15), and between hemorrhagic manifestation and recurrence (P = .002, RR = 3.17). There was no significant difference between packing and recurrence, between initial angiographic result and recurrence, between percentage of complex coils and recurrence, between aneurysm location and recurrence, or between multiplicity of aneurysms and recurrence.

Conclusion: More angiographic recurrences are detected over time. Complex coils do not augment aneurysm packing. Packing is not related to protection against recurrence.

© RSNA, 2007

References

  • 1 Gallas S, Pasco A, Cottier JP, et al. A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils. AJNR Am J Neuroradiol 2005; 26: 1723–1731. MedlineGoogle Scholar
  • 2 Molyneux AJ, Kerr RS, Yu LM, et al. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 2005; 366: 809–817. Crossref, MedlineGoogle Scholar
  • 3 Wiebers DO, Whisnant JP, Huston J 3rd, et al. Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet 2003; 362: 103–110. Crossref, MedlineGoogle Scholar
  • 4 Thornton J, Bashir Q, Aletich VA, Debrun GM, Ausman JI, Charbel FT. What percentage of surgically clipped intracranial aneurysms have residual necks? Neurosurgery 2000; 46: 1294–1298. Crossref, MedlineGoogle Scholar
  • 5 Kai Y, Hamada J, Morioka M, Yano S, Kuratsu J. Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: correlation between coil packing ratio and coil compaction. Neurosurgery 2005; 56: 785–792. Crossref, MedlineGoogle Scholar
  • 6 Kawanabe Y, Sadato A, Taki W, Hashimoto N. Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: correlation between coil packing density and coil compaction. Acta Neurochir (Wien) 2001; 143: 451–455. Crossref, MedlineGoogle Scholar
  • 7 Bescos JO, Slob MJ, Slump CH, Sluzewski M, van Rooij WJ. Volume measurement of intracranial aneurysms from 3D rotational angiography: improvement of accuracy by gradient edge detection. AJNR Am J Neuroradiol 2005; 26: 2569–2572. MedlineGoogle Scholar
  • 8 Sluzewski M, van Rooij WJ, Slob MJ, Bescos JO, Slump CH, Wijnalda D. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology 2004; 231: 653–658. LinkGoogle Scholar
  • 9 Tamatani S, Ito Y, Abe H, Koike T, Takeuchi S, Tanaka R. Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms. AJNR Am J Neuroradiol 2002; 23: 762–767. MedlineGoogle Scholar
  • 10 Slob MJ, van Rooij WJ, Sluzewski M. Coil thickness and packing of cerebral aneurysms: a comparative study of two types of coils. AJNR Am J Neuroradiol 2005; 26: 901–903. MedlineGoogle Scholar
  • 11 Raymond J, Guilbert F, Weill A, et al. Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 2003; 34: 1398–1403. Crossref, MedlineGoogle Scholar
  • 12 Rinkel GJ, Djibuti M, Algra A, van Gijn J. Prevalence and risk of rupture of intracranial aneurysms: a systematic review. Stroke 1998; 29: 251–256. Crossref, MedlineGoogle Scholar
  • 13 Sluzewski M, van Rooij WJ, Rinkel GJ, Wijnalda D. Endovascular treatment of ruptured intracranial aneurysms with detachable coils: long-term clinical and serial angiographic results. Radiology 2003; 227: 720–724. LinkGoogle Scholar
  • 14 Malek AM, Higashida RT, Phatouros CC, Dowd CF, Halbach VV. Treatment of an intracranial aneurysm using a new three-dimensional-shape Guglielmi detachable coil: technical case report. Neurosurgery 1999; 44: 1142–1144. Crossref, MedlineGoogle Scholar
  • 15 Piotin M, Iijima A, Wada H, Moret J. Increasing the packing of small aneurysms with complex-shaped coils: an in vitro study. AJNR Am J Neuroradiol 2003; 24: 1446–1448. MedlineGoogle Scholar
  • 16 Slob MJ, Sluzewski M, van Rooij WJ. The relation between packing and reopening in coiled intracranial aneurysms: a prospective study. Neuroradiology 2005; 47: 942–945. Crossref, MedlineGoogle Scholar
  • 17 Piotin M, Gailloud P, Bidaut L, et al. CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms: an experimental study. Neuroradiology 2003; 45: 404–409. Crossref, MedlineGoogle Scholar
  • 18 Piotin M, Daghman B, Mounayer C, Spelle L, Moret J. Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. AJNR Am J Neuroradiol 2006; 27: 839–842. MedlineGoogle Scholar
  • 19 Goddard JK, Moran CJ, Cross DT 3rd, Derdeyn CP. Absent relationship between the coil embolization ratio in small aneurysms treated with a single detachable coil and outcomes. AJNR Am J Neuroradiol 2005; 26: 1916–1920. MedlineGoogle Scholar
  • 20 Sorteberg A, Sorteberg W, Rappe A, Strother CM. Effect of Guglielmi detachable coils on intraaneurysmal flow: experimental study in canines. AJNR Am J Neuroradiol 2002; 23: 288–294. MedlineGoogle Scholar

Article History

Published in print: 2007