True-Lumen Collapse in Aortic Dissection

Part II. Evaluation of Treatment Methods in Phantoms with Pulsatile Flow

PURPOSE: To discover and evaluate the effective treatment methods to prevent or relieve true-lumen collapse in models of aortic dissection.

MATERIALS AND METHODS: Two phantoms were built to simulate type B aortic dissection. After true-lumen collapse was induced, experiments were conducted to evaluate the effectiveness of clinically relevant variables in relieving the collapse. Variables included entry-tear size, branch-vessel flow distribution, distal reentry communication between the true and false limbs, aortic fenestrations, and pump output. To test the effect of closing the entry tear, a stent-graft was deployed over the entry tear under physiologic conditions in a mock-flow loop. The difference in the effect of each variable on the prevention and relief of true-lumen collapse was also investigated.

RESULTS: It was more difficult to relieve true-lumen collapse than it was to prevent it. Placement of a stent-graft over the entry tear was the most effective method of relieving true-lumen collapse. Less-effective procedures included opening a false-lumen outflow branch and opening the distal reentry branch. Opening the fenestration-branch loops, meant to simulate the creation of artificial fenestrations in the intimal flap, did not relieve true-lumen collapse.

CONCLUSION: The definitive treatment for true-lumen collapse in aortic dissection is direct repair of the entry tear to decrease false-lumen inflow. Otherwise, increasing the false-lumen outflow and/or creating distal fenestrations between the true and false lumina distal to the level of the compromised aortic branch are less-effective alternatives.

References

  • 1 Williams DM, Lee DY, Hamilton BH, et al. The dissected aorta: percutaneous treatment of ischemic complications—principles and results. JVIR 1997; 8:605-625.
  • 2 Pinet F, Froment JC, Guillot M, et al. Prognostic factors and indications for surgical treatment of acute aortic dissections: a report based on 191 observations. Cardiovasc Intervent Radiol 1984; 7:257-266.
  • 3 Cambria RP, Brewster DC, Gertler J, et al. Vascular complications associated with spontaneous aortic dissection. J Vasc Surg 1988; 7:199-209.
  • 4 Fann JI, Sarris GE, Mitchell RS, et al. Treatment of patients with aortic dissection presenting with peripheral vascular complications. Ann Surg 1990; 212:705-713.
  • 5 Williams DM, Brothers TE, Messina LM. Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum. Radiology 1990; 174:450-452.
  • 6 Slonim SM, Nyman UR, Semba CP, Miller DC, Mitchell RS, Dake MD. True lumen obliteration in complicated aortic dissection: endovascular treatment. Radiology 1996; 201:161-166.
  • 7 DeBakey ME, McCollum CH, Crawford ES, et al. Dissection and dissecting aneurysms of the aorta: twenty-year follow-up of five hundred twenty-seven patients treated surgically. Surgery 1982; 92:1118-1134.
  • 8 Glower DD, Fann JI, Speier RH, et al. Comparison of medical and surgical therapy for uncomplicated descending aortic dissection. Circulation 1990; 82(suppl 4):39-46.
  • 9 Miller DC, Mitchell RS, Oyer PE, et al. Independent determinants of operative mortality for patients with aortic dissections. Circulation 1984; 70(suppl 1):153-164.
  • 10 Crawford ES. The diagnosis and management of aortic dissection. JAMA 1990; 264:2537-2541.
  • 11 DeSantis RW, Doroghazi RM, Austen WG, Buckley MJ. Aortic dissection. N Engl J Med 1987; 317:1060-1067.
  • 12 Elefteriades JA, Hammond GL, Gusberg RJ, Kopf GS, Baldwin JC. Fenestration revisited: a safe and effective procedure for descending aortic dissection. Arch Surg 1990; 125:786-790.
  • 13 Shah PM, Clauss RH. Dissecting hematoma presents as acute lower limb ischemia: diagnostic patient profile and management. J Cardiovasc Surg 1983; 24:649-653.
  • 14 Slonim SM, Nyman U, Semba , Miller DC, Mitchell S, Dake MD. Aortic dissection: percutaneous management of ischemic complications with endovascular stents and balloon fenestration. J Vasc Surg 1996; 23:241-253.
  • 15 Williams DM, Lee DY, Hamilton BH, et al. The dissected aorta. III. Anatomy and radiologic diagnosis of branch-vessel compromise. Radiology 1997; 203:37-44.
  • 16 Young JR, Dramer J, Humphries AW. The ischemic leg: a clue to dissecting aneurysm. Cardiovasc Clin 1975; 7:201-205.
  • 17 Merkelbach JW, Van Rhede Vanderkloot JF. Intermittent peripheral arterial occlusion as a result of a dissecting aneurysm. Arch Chir Neerl 1970; 22:7-13.
  • 18 Schoon IM, Holm J, Sudow G. Lower extremity ischemia in aortic dissection: report of three cases. Scand J Thorac Cardiovasc Surg 1985; 19:93-95.
  • 19 Williams DM, LePage MA, Lee DY. The dissected aorta. I. Early anatomic changes in an in vitro model. Radiology 1997; 203:23-31.
  • 20 Park JH, Chung JW, Cho YK, Kim SH, Ahn H, Oh BH. Percutaneous fenestration of aortic dissection: salvage of an ischemic solitary left kidney. Cardiovasc Intervent Radiol 1997; 20:146-154.

Article History

Published in print: Jan 2000