Intracranial Arteriovenous Malformations: Real-Time Auto-triggered Elliptic Centric-ordered 3D Gadolinium-enhanced MR Angiography—Initial Assessment
Abstract
Auto-triggered elliptic centric-ordered three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography was compared with 3D multiple overlapping thin-slab acquisition time-of-flight (TOF) MR angiography in the evaluation of intracranial arteriovenous malformations (AVMs) in 10 patients. Intraarterial digital subtraction angiography (DSA) was the reference standard. Gadolinium-enhanced MR angiograms were found to be equivalent to DSA images in AVM component depiction in 70%–90% of cases and were consistently superior to TOF MR angiograms.
References
- 1 Ehricke HH, Schad LR, Gademann G, Wowra B, Engenhart R, Lorenz WJ. Use of MR angiography for stereotactic planning. J Comput Assist Tomogr 1992; 16:35-40.
- 2 Mehta MP, Petereit D, Turski P, Gehring M, Levin A, Kinsella T. Magnetic resonance angiography: a three-dimensional database for assessing arteriovenous malformations—technical note. J Neurosurg 1993; 79:289-293.
- 3 Marchal G, Bosmans H, Van Fraeyenhoven L, et al. Intracranial vascular lesions: optimization and clinical evaluation of three-dimensional time-of-flight MR angiography. Radiology 1990; 175:443-448.
- 4 Petereit D, Mehta M, Turski P, et al. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database. Int J Radiat Oncol Biol Phys 1993; 25:309-313.
- 5 Kauczor HU, Engenhart R, Layer G, et al. 3D TOF MR angiography of cerebral arteriovenous malformations after radiosurgery. J Comput Assist Tomogr 1993; 17:184-190.
- 6 Kondziolka D, Lunsford LD, Kanal E, Talagala L. Stereotactic magnetic resonance angiography for targeting in arteriovenous malformation radiosurgery. Neurosurgery 1994; 35:585-590.
- 7 Wallace C, Bourekas C. Brain arteriovenous malformations. Neuroimaging Clin N Am 1998; 8:383-399.
- 8 Blatter DD, Parker DL, Ahn SS, et al. Cerebral MR angiography with multiple overlapping thin slab acquisition. Radiology 1992; 183:379-389.
- 9 Marks MP. Vascular malformations. Magn Reson Imaging Clin N Am 1995; 3:485-491.
- 10 Spigelmann R, Friedman WA, Bova FJ. Limitations of angiographic target localization in planning radiosurgical treatment. Neurosurgery 1992; 30:619-624.
- 11 Klisch J, Strecker R, Hennig J, Schumacher M. Time-resolved projection MRA: clinical application in intracranial vascular malformations. Neuroradiology 2000; 42:104-107.
- 12 Essig M, Knopp MV, Schoenberg SO, et al. Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography (abstr). Proceedings of the Sixth Meeting of the International Society for Magnetic Resonance in Medicine Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 1998; 1285.
- 13 Hoggard N, Wilkinson ID, Warren DJ, Griffiths PD. The Spetzler grading of cerebral arteriovenous malformations on MR DSA compared to conventional catheter angiography (abstr). Proceedings of the Eighth Meeting of the International Society for Magnetic Resonance in Medicine Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2000; 1237.
- 14 Derbyshire AJ, Kim JK, Farb RI, Wright GA. Automated contrast bolus detection and triggered true centric 3D MRA of the carotid arteries (abstr). Proceedings of the Sixth Meeting of the International Society for Magnetic Resonance in Medicine Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 1998; 766.
- 15 Maki J, Prince M, Londy FJ, Chenevert TL. The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality. J Magn Reson Imaging 1996; 6:642-651.
- 16 Wilman AH, Riederer SJ, King BF, Debbins JP, Rossman PJ, Ehman RL. Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries. Radiology 1997; 205:137-146.
- 17 Wilcock DJ, Jaspan T, Worthington BS. Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation. Clin Radiol 1995; 50:526-532.
- 18 Parker DL, Tsuruda JS, Goodrich KC, Alexander AL, Buswell HR. Contrast-enhanced magnetic resonance angiography of cerebral arteries: a review. Invest Radiol 1998; 33:560-572.
- 19 Prince MR, Chenevert TL, Foo TKF. Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast material arrival in the aorta. Radiology 1997; 203:109-114.
- 20 Isoda H, Takehara Y, Isogai S, et al. Technique for arterial-phase contrast-enhanced three-dimensional MR angiography of the carotid and vertebral arteries. AJNR Am J Neuroradiol 1998; 19:1241-1244.
- 21 Huston J, III, Fain SB, Riederer SJ, Wilman AH, Bernstein MA, Busse RF. Carotid arteries: maximizing arterial to venous contrast in fluoroscopically triggered contrast enhanced MR angiography with elliptic centric view ordering. Radiology 1999; 211:265-273.
- 22 Kim JK, Farb RI, Wright GA. Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography. Radiology 1998; 206:283-289.
- 23 Isoda H, Takehara Y, Isogai S, et al. Software-triggered contrast-enhanced three-dimensional MR angiography of the intracranial arteries. AJR Am J Roentgenol 2000; 174:371-375.
- 24 Milburn JM, Moran CJ, Cross DT, III, Diringer MN, Pilgram TK, Dacey RG, Jr. Effect of intraarterial papaverine on cerebral circulation time. AJNR Am J Neuroradiol 1997; 18:1081-1085.
- 25 Riederer SJ, Bernstein MA, Breen JF, et al. Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies. Radiology 2000; 215:584-593.
- 26 Foo TKF, Saranathan M, Prince MR, Chenevert TL. Automated detection of bolus arrival and initiation of data acquisition in fast, three dimensional, gadolinium-enhanced MR angiography. Radiology 1997; 203:275-280.
- 27 Isogai S, Takehara Y, Isoda H, et al. Pitfalls in enhanced MR angiography: view order and contrast bolus trajectory (abstr). Proceedings of the Sixth Meeting of the International Society for Magnetic Resonance in Medicine Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 1998; 177.
- 28 Kim JK, Farb RI, Derbyshire JA, et al. Initial blinded comparison of first pass centric 3D Gd-MRA, 2DTOF MRA and IADSA of the carotid arteries (abstr). Proceedings of the Seventh Meeting of the International Society for Magnetic Resonance in Medicine Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 1999; 204.
- 29 Heiserman JE, Dean BL, Hodak JA, et al. Neurologic complications of cerebral angiography. AJNR Am J Neuroradiol 1994; 15:1401-1407.
- 30 Parker DL, Goodrich KC, Alexander AL, et al. Optimized visualization of vessels in contrast enhanced intracranial MR angiography. Magn Reson Med 1998; 40:873-882.
- 31 Fain SB, Riederer SJ, Grimm RC, Huston J, III. Real-time contrast-bolus-synchronized k-space sampling with flip angle modulation (abstr). Proceedings of the Seventh Meeting of the International Society for Magnetic Resonance in Medicine Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 1999; 1887.